page 33
www.CentSys.com
9.3.4.1. Cutting the Gate
Bracket
Determine the E-Value for this
specific installation by following
the example in section 9.3.1 and
substituting the hinge depth of
this specific installation into the
calculation.
Cut the Gate Bracket to the E-Value
length in order to mount the bracket
to the gate and achieve the correct
D-Value.
FIGURE 26. CUT THE GATE BRACKET
Cut Gate Bracket
to length
D
E
OPERA
TOR
INS
TALLATION
-
INW
ARD
OPENING
GA
TE
The measurement is taken
from the centre of the hole
of the Gate Bracket as
indicated in Figure 26.
FIGURE 27. ATTACH THE GATE BRACKET ONTO A NON-STEEL GATE
Weld brackets
together
Fasten the welded Gate
Bracket to the gate
Gate
Bracket
Wall Bracket
Mounting Plate
(ordered
separately)
9.3.4.2. Making Up a Bracket for a Non-steel Gate
In the case where the gate is not manufactured from steel or the mounting point for the
front bracket is not on a steel section of the gate, it is necessary to make up a mounting
bracket for the Gate Bracket. This is easily achieved by purchasing a second Wall
Mounting Bracket and welding the Gate Bracket to the Wall Bracket Mounting Plate.