www.CentSys.com
10.3. Physical installation - Outward opening
10.3.1. Step 1: Determine the Gate Bracket Length (E-Value)
It is essential to first determine whether the correct Gate Bracket length (E-Value) can be
achieved according to Table 8 and 9 (Installation Table) as described below.
FIGURE 38. DETERMINE THE GATE BRACKET LENGTH
Gate
E
D
Pillar
Gate Bracket
Gate hinge center point
Measure hinge depth
(25mm – as example)
Gate front face
(Where Gate Bracket
is attached to)
The most optimal installation position for a
VERT-X
90° outward opening is:
• A = 160
• B = 140
• C = 638
• D = 115
Therefore this installation position will be described in this Manual.
(Refer to Figure 38 and Tables 8 and 9 for details).
Measure the hinge depth from the centre of the hinge point to the face of the gate.
If the hinge depth is greater than 30mm, then refer to Section 6.6.
(for this example, a measurement of 25mm will be used).
E-Value = D-Value MINUS Hinge Depth
Thus: E = 115mm – 25mm = 90mm
If the E-value is greater than 82.5mm, you may choose any installation position shown in
Table 6 (see note above for optimal installation).
If the E-Value is less than 80mm (for 90° outward opening) or less than 85mm
(for 100° outward opening), the operator
WILL
foul against the gate during operation.
In order to rectify this, refer to Section 6.4.
OPERA
TOR
INS
TALLATION
-OUTW
ARD
OPENING
GATE
S
ECTION
1
0
Содержание VERT-X
Страница 8: ...page 8 www CentSys com This section has been left blank intentionally...
Страница 53: ...page 53 www CentSys com Notes NOTES...
Страница 54: ...page 54 www CentSys com Notes...
Страница 55: ...page 55 www CentSys com NOTES Notes NOTES...