page 20
www.CentSys.com
FIGURE 6. SIDE WALL LIMITATION FOR A 90° INWARD OPENING GATE
Wall minimum
must be greater
than 190mm
Pillar to gate hinge point
(60mm maximum)
Wall
Gate in closed position
Gate Hinge Point
Gate in open position
Gate opening 90º
or less
6.4. Inward Opening Installation - 90º or less
Figure 6 shows the minimum wall clearance and maximum pillar to gate hinge point
distance for an inward opening gate leaf opening to an angle of 90º or less.
The pillar to gate hinge point maximum ensures that the operator does not foul against
the pillar when installed. The minimum wall clearance ensures that there is enough space
to install the operator according to the installation tables.
Side wall
6.3. Key Terms Used in this Section
6.3.1. Pillar maximum
The maximum allowable distance measured from the centre of the gate hinge to the edge
of the pillar.
6.3.2. Wall minimum
This value denotes the minimum amount of space needed to install the operator and is
measured from the side wall to the gate when the gate is in the open position.