page 13
www.CentSys.com
S
PECIFICA
TIONS
3.3. V-Series Controller
Maximum motor current per channel
15A (fused)
Maximum input voltage
18V DC
Standby current draw
48mA
Maximum solenoid current draw
2A DC
Maximum auxillary output current
3A (Resettable Electronic Fuse)
Collision detection
Current sense and redundant optical
Position and trajectory
Redundant optical
Temperature range
-20°C to +60°C
TABLE 2
Maximum Allowable gate Mass
Length (m)
Up to
1.5m
Up to
2m
Up to
2.5m
Up to
3m
Mass (kg)
600kg
335kg
215kg
150kg
TABLE 3
3.5. Maximum Allowable Gate Mass and coverage
An electronic lock can be fitted to improve the security of the system
3.4. Lightning Protection
The
V-Series
electronic controller utilises the same proven surge protection philosophy
that is used in all our products. While this does not guarantee that the unit will not
be damaged in the event of a lightning strike or power surge, it greatly reduces the
likelihood of such damage occurring. The earth return for the surge protection is provided
via the mains power supply earth. In order to ensure that the surge protection is
effective, it is essential that the unit is properly earthed.