3 - CONTROLS/INSTRUMENTS
Suspending automatic regeneration
4FKEJV-001ZA
3
Automatic regeneration is suspended if the Diesel Particulate Diffuser switch is pressed during regeneration.
If the switch is held for 3 seconds or more during automatic regeneration, operation moves to optional manual regen-
eration. (The orange lamp blinks.)
Do not press the switch again if manual regeneration is not wanted.
The orange lamp goes out.
The diffuser may become faulty if operation is continued when automatic regeneration is suspended for a long time.
Move to a safe place as quickly as possible and execute regeneration. Operation changes to manual regeneration if
automatic regeneration is suspended for a long time.
1. In automatic regeneration
• The green lamp is lit.
• The following message is displayed cyclically.
Auto
DPD
Re-gen
2. Carry out either of the following.
• Pressing the switch.
Push
DPD
switch to activate
3. Automatic regeneration is suspended.
• The green lamp goes out.
• The following message is displayed.
Push
DPD
switch to activate
4. Press the switch once to restart automatic regeneration.
• Automatic regeneration restarts within several seconds.
3-39
Содержание CX300C
Страница 6: ......
Страница 18: ...1 GENERAL INFORMATION 1 12...
Страница 28: ...2 SAFETY INFORMATION QNTTT2 011B_TU 3 2 10...
Страница 50: ...2 SAFETY INFORMATION 2 32...
Страница 68: ...3 CONTROLS INSTRUMENTS System display and function control panel MUC8LU 034Z 1 MUC8LU 044Z 2 3 18...
Страница 130: ...3 CONTROLS INSTRUMENTS 3 80...
Страница 157: ...4 OPERATING INSTRUCTIONS 4 Operate the arm control to unhook the tool KKZVLU 024A 14 4 27...
Страница 172: ...4 OPERATING INSTRUCTIONS 4 42...
Страница 182: ...5 TRANSPORT OPERATIONS 5 10...
Страница 272: ...6 MAINTENANCE 6 90...
Страница 280: ...8 SPECIFICATIONS Working range 4M8ORU 002A 2 See next page for the values 8 6...
Страница 282: ...8 SPECIFICATIONS 8 8...