6 - MAINTENANCE
Replacing the reservoir breather filter ele-
ment
19IXC6-003
10
1. Press the button
(1)
to release all pressure in the hy-
draulic reservoir.
2. Remove the nut
(2)
and the cover
(3)
from the
breather.
3. Remove and discard the used filter element
(4)
.
4. Install a new element
(4)
, making sure the seal
(5)
is
facing upwards.
5. Install the cover
(3)
as well as the nut
(2)
.
19IXC6-002
11