Maintenance and Cleaning
DPM IV
86
Operating Manual
05.18
8.4 Replacing the Printhead
CAUTION!
The printhead can be damaged by static electricity discharges
and impacts!
Set up direct print module on a grounded, conductive
surface.
Ground your body, e.g. by wearing a grounded
wristband.
Do not touch contacts on the plug connections.
Do not touch printing line (5) with hard objects or your
hands.
A
B
A
C
C
Figure 20
1.
Open the cover of print mechanics.
2.
Remove transfer ribbon material.
3.
Move printhead unit in an appropriate service position.
4.
Remove printhead cable (C).
5.
Remove screws (A) and afterwards the printhead (B).
Removing the
printhead