Technical Data
DPM IV
24
Operating Manual
05.18
Plug Connector
Type
D-Sub connector High Density
26-pin. / connector
Manufacturer
W+P-Products
Reference number
110-26-2-1-20
Output Voltages (connected with GND-PE)
+ 24 V / 1 A
Fuse: Polyswitch / 30 V / 1 A
+ 5 V / 1 A
Fuse: Polyswitch / 30 V / 1 A
Port 1 - 15
Input
Tension
5 VDC … 24 VDC
Impedance
47Ω + (100nF || 10 kΩ)
Output
Tension
5 VDC … 24 VDC
Impedance
47Ω + (100nF || 10 kΩ || 47Ω)
Current max.
High +15 mA
Low -15 mA
Port 16
Input
Tension
5 VDC … 24 VDC
Impedance
100nF || 10 kΩ
Output
Tension
5 VDC … 24 VDC
Impedance
100nF || 10 kΩ
Current max.
High +500 mA (Darlington BCP56-16)
Low - 500 mA (Darlington BCP56-16)
Optocoupler
Output
TCMT4106, CTR 100% - 300%, Vishay or
TLP281-4(GB), CTR 100% - 600%, Toshiba
Input
TCMT4106, CTR 100% - 300%, Vishay or
TLP281-4(GB), CTR 100% - 600%, Toshiba
Input
Option 2nd LED
TCMT4600, CTR 80% - 300%, Vishay or
TLP280-4, CTR 33% - 300%, Toshiba