Function Menu
DPM IV
48
Operating Manual
05.18
6.5 I/O Parameters
6.5.1 I/O Port Parameters 1-8
Input print start
Input reset error
Input reset counter
Disabled
Disabled
Disabled
Disabled
Disabled
6.5.2 I/O Port Parameters 9-16
Output error
Output print order active
Output generation
Output printing
Output ready
Output error
Output backfeed
Output ribbon prior warning
6.5.3 General Parameters
Selection of existing configurations
Std_Direct
(factory setting),
StdFileSelDirect, SP_Direct0
or
Old_Direct0
.
The corresponding assignment is indicated in chapter 4.1, page 19.
Indication of debounce time of the dispenser input. The setting range
of the debounce time is between 0 and 100 ms.
In case the start signal is not clear then you can debounce the input
by means of this menu item.
Indication in time per second of the delay for the start signal.
Value range: 0.00
… 9.99.
I/O profile
Debounce
Start signal delay
(intermittent mode)