25
DISPLAY MODE
Using the
PROG
button you can access the following functions
in sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
CSPF
= Enable digital safety edge
0
= Digital safety edge disabled
1
= Digital safety edge enabled
10 sec
PRESS PROG
Each time "
PROG
" is pressed the
selection switches between “
0
” and “
1
”.
10 s after the last modification the
mode will quit automatically and the
selected values will be saved (e.g. 1)
10 sec
10 sec
When the ("
TD-TB-FTCI,CSP,CSPF
") inputs are
activated the warning and courtesy lights will light up.
10 sec
5 sec
10 sec
The segments regarding the command status (LED
“ON” = command active) and safety status (LED “ON”
= safety device at rest) light up.
The number of manoeuvres appears on the display.
This number always remains visible until you change
the setting. Once
999999
has been exceeded the
lighting up of the decimal point on the display equals 1
m the six figure number.
In the "
test
" mode (only activated when the motor has
stopped) it is possible to check the status of the
command and safety devices. The warning lights will
activate once, each time a ("
TD-TB-FTCI-CSP-CSPF
")
command is received. In this mode you can activate
serial line communication by using the external
program, which is to be connected to the
CSER
connection via cable (fig. 31). While communication is
active dashes will appear on the display; after 5
seconds of inactivity you will be moved back to the
"
test
" mode. To return to the normal operating mode
press the button again “
test
” will appear, then wait for
10 seconds.
Memorising the DIP-SWITCH settings and displaying
the firmware version (e.g. “
10
”)
drA
= Setting the reclosing function with an obstacle:
- “1” = the programmer tries to close three times.
- “0” = the programmer tries to close once.
PRESS PROG
Connect the
programming device
(
CSER
) and activate it.
PRESS PROG
10 sec
PRESS
PROG
PRESS PROG
Each time "
PROG
" is pressed the
selection switches between “
1
” and “
0
”.
10 sec
10 s after the last modification the
mode will quit automatically and the
selected values will be saved (e.g. 0)
10 sec
SNS
= Setting the current sensor.
1 = motor consu 1 amp
2 = motor consu 2 amps
3 = motor consu 3 amps
10 sec
PRESS
PROG
PRESS PROG
Each time "
PROG
" is pressed the
selection switches from “
1
” to “
3
”.
10 s after the last modification the
mode will quit automatically and the
selected values will be saved (e.g. 3)
10 sec
10 sec
dSt
=
Setting the distance from the opening
direction travel limit (approximate values):
- “
0
” =
0
centimetres - “
1
” =
1
centimetre
- “
2
” =
2
centimetres - “
3
” =
3
centimetres
10 sec
PRESS PROG
Each time "
PROG
" is pressed the
selection switches from “
0
” to “
3
”.
10 s after the last modification the
mode will quit automatically and the
selected values will be saved (e.g. 1)
10 sec
10 sec
SC
= Safety contact selection (
N.C./8.2 kOhm
)
0 = CSP, TB, FTCI: contact N.C.
1 = CSP:
8.2 kOhm /
TB, FTCI: contact N.C.
2…7 see “Safety contact selection” on page 28
10 sec
PRESS
PROG
PRESS PROG
Each time "
PROG
" is pressed the
selection switches from “
0
” to “
7
”.
10 s after the last modification the
mode will quit automatically and the
selected values will be saved (e.g. 1)
10 sec
10 sec
PRESS
PROG
PRESS
PROG
The status of the security devices
TB
,
FTCI, CSP,
CSPF
are always shown on the display.
10 sec
PRESS PROG
PRESS PROG
PRESS PROG
- access the "
test
" mode;
- enabling/disabling automatic reclosing in the presence of an obstacle;
- setting the current sensor level;
- setting the distance from the opening direction travel limit;
- safety contact selection (
N.C./8.2 kΩ
);
- enabling the digital safety edge.