126
13.62 Dome Mode Setting Verification
Camera Control Command Type 1
Function
Returns the dome mode setting value.
Command
00BDh
Length
2 byte
Parameter
Value 01h
Length 2
byte
Status
Range 00h~03h
00h~01h (Ver.6-08 and up)
Reference •Dome mode setting value
00h: Select cam path 0 to 9
01h: Select cam path 0 to 8
02h: Select cam path 0 to 7
03h: Select cam path 0 to 6
•Setting value of cam path 0 to 9
0: INF
1: 450cm
2: 201cm
3: 120cm
4: 80cm
5: 40.7cm 6: 9.2cm
7: 1cm
[Ver.6-08 and up]
00h: Dome mode OFF
01h: Dome mode ON
•The Dome mode setting is retained even after the power is turned off.
Format of Control Code
d0 d1 d2
d3
d4
d5
d6 d7
Header
Device Num
Command
Parameter
End mark
FFh 30h
3Xh
00h
BDh
30h
31h EFh
Answer Format
No Error
d0 d1 d2 d3 d4 d5 d6
d7
Header
Device Num
Error Code
Status
End mark
FEh 30h
3Xh
30h
30h s0 s1 EFh
⇓
Setting value indicates in 2 figures hexadecimal and returns ASCII code value
Noise Reduction s0 s1
Doom setting value : 00h
⇒
30h 30h
Doom setting value : 01h
⇒
30h 31h
Doom setting value : 02h
⇒
30h 32h
Doom setting value : 03h
⇒
30h 33h
Generated Error
d0 d1
d2 d3 d4 d5
Header
Device Num
Error Code
End mark
FEh 30h
3Xh e0 e1 EFh
⇓
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value
Example: e0 e1
In case of Parameter Error :
01010000B
⇒
50h
⇒
35h 30h
In case of Mode Error :
10010000B
⇒
90h
⇒
39h 30h