161
14.27
Cascade
OFF
System Control Command Type 1
Function
To release Cascade Connection OFF.
Command 008Fh
Length 1
byte
Parameter
Value 0h
Status None
Reference •Cascade connection status comes out OFF by default at the moment of
power ON.
•Multiple VC-C50i's unable to control in status of cascade OFF.
•Device number of this command is only "3030h"
•Usable device number in cascade OFF, is only "3030h"
•
Cascade ON/OFF
commands are effective for all VC-C50i connected even
in a cascade OFF status.
•To force to stop Pan/Tilt operation by this command except operating
pedestal initialize.
•Necessary to issue this command before issuing
Cascade ON
command (
14.28
).
Format of Control Code
d0 d1
Header
d2 d3 d4 d5
d6
Device Num
Command
Parameter
End mark
FFh 30h 30h 00h 8Fh 30h
EFh
Answer Format
d0 d1 d2 d3 d4 d5
Header
Device Num
Error Code
End mark
FEh 30h 30h e0 e1 EFh
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :
00000000B
⇒
00h
⇒
30h 30h
In case of Mode Error :
10010000B
⇒
90h
⇒
39h 30h
Condition of Error flag to be set
Mode Error
•In case of operating MENU by
Local Mode.