11
Example 3: The case using Remote Control Through Function
The details are referring to
9. Function of Remote Control
.
As shown below, there are some cases that the commands and remote control through
data are generated at the same time, while remote control through function turns on the
RTS line of computer. In this case, the software of computer must correspond to full duplex.
Computer Side
RTS
TXD
(Control Command)
Remote
RXD
(Answer)
Example 4: The case using the Function of Command Termination Notification
The details are referring to
6. Function of Command Termination Notification
.
As shown in the example below, when the command termination notification function is used,
it is possible that both the command and command termination notification will be generated
at the same time while the RTS line of the computer is on. For this reason, the control software
of the computer must support full duplex.
Computer Side
RTS
TXD
(Control Command)
Execute
Command 1
Answer 1
Command 2
Remote Control ON Data
Answer 2
Command 1
Answer 1
Command 2
Command Termination Notification
Answer 2
ON
RXD
(Answer)