144
To return extended information of inside status of VC-C50i (operation status)
14.15 Extended Operation Status Request
System Control Command Type 1
Function
Command
0086h
Parameter
0h
Length 5
byte
Status
Value
Value of operation status which indicates inside status
(20 bits)
Reference The followings show status, in case that each bit is 1 among of status.
(MSB)
b19
In process of Menu
b18
Local Control Mode
b11
Tilting under operation
1 1 Not
use
Not
use
b17
Time
unset
b16
Date
unset
b15
Not
use
b14
Not
use
b13
Exposure(AE) mode not AUTO
b12
White balance mode not AUTO
b10
Tilt movable limit position
b9
Panning under operation
b8
Pan movable limit position
b7
Zooming under operation
b6
Remote Control operate OFF
b5
Camera Power OFF
b4
Unexecuting Pedestal Initialize
b3
Shutter speed flag 1
b2
Shutter speed flag 2
b3
b2
NTSC
PAL
0 0 program
program
0 1 1/60
1/50
1 0 1/100
1/120
b1
Manual Focus mode
b0
Focusing under operation
(LSB)
•The information of b0 ~ b11 is equal to the information of
14.14 Operation
Status Request.
•In case that b19 is 1 (In process of Menu), unable to host control mode.
•In case that b18 is 1 (Local Control Mode), unable to control through host.
Format of Control Code
d0 d1 d2 d3 d4 d5
d6
Header
Device Num
Command
Parameter
End mark
FFh 30h 3Xh 00h 86h 30h
EFh