193
16.7 Cascade Global Assignment
In case of VC-C50i controlled simultaneously in cascade connection, it is necessary
to assign device num "3030"
Example of Termination Notification ON, Global Notification ON by Cascade ON
Host
VC-C50i 1st unit 2nd unit 3rd
unit
(1) System Control Command
Cascade ON
Initialize Start
Initialize End
Initialize End
Initialize End
Control Mode
Change
(2)
Answer
(ACK)
(3) System Control Command
Global Notification Setting ON
(4)
Answer
(ACK)
(5) System Control Command
Global Notification Setting ON
(6)
Answer
(ACK)
(7)
Global
Notification
(8) Pedestal Control Command
Pedestal Initialize 1
(9)
Answer
(ACK)
(10)
Global
Notification
(11) Termination Notification (1st unit)
(12) Termination Notification (3rd unit)
(13) Termination Notification (2nd unit)
Corresponding Frame Code
Command/Answer
(1)
FF 30 30 00 8F 31 EF
(2)
FE 30 33 30 30 EF
(3)
FF 30 30 00 94 31 EF
(4)
FE 30 33 30 30 EF
(5)
FF 30 30 00 95 31 EF
(6)
FE 30 33 30 30 EF
(7)
F8 30 33 30 30 30 30 EF
(8)
FF 30 30 00 58 30 EF
(9)
FE 30 33 30 30 EF
(10)
F8 30 33 30 30 30 30 EF
(11)
FA 30 31 00 58 30 EF
(12)
FA 30 33 00 58 30 EF
(13)
FA 30 32 00 58 30 EF