176
14.39 Default Setting
System Control Command Type 1
Function
To initialize in status of factory setting.
Command
0093h
Length 1
byte
Parameter
Value 0h
Status
None
Reference •To return to status of factory setting at shipping from factory.
(to re-write memory data of built in nonvolatile IC)
•By this command, all items except the followings reset default values at the
shipping status from factory.
•Pedestal Initial Information
•Date, Time setting
•Indication Character setting
•By this command, camera section is rest.
•By this command, communication section with host is reinitialized.
(Baud rate: 9600 bps, stop: 1 bit)
•Host Control Mode unchanged, but cascade OFF status comes out.
•By this command, CTS signal of host stop one second OFF.
Note:
•Necessary to issue another commands after two seconds passed from issuing
this command.
Format of Control Code
d0 d1 d2 d3 d4 d5
d6
Header
Device Num
Command
Parameter
End mark
FFh 30h 3Xh 00h 93h 30h
EFh
Answer Format
d0 d1 d2 d3 d4 d5
Header
Device Num
Error Code
End mark
FEh 30h 3Xh e0 e1 EFh
⇓
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :
00000000B
⇒
00h
⇒
30h 30h
In case of Busy :
00010000B
⇒
10h
⇒
31h 30h
In case of Parameter Error :
01010000B
⇒
50h
⇒
35h 30h
In case of Mode Error :
10010000B
⇒
90h
⇒
39h 30h
Condition of Error flag to be set
Busy
•In case of executing of
Camera Control
command.
•In case of executing
Pedestal Control
command.
•In case of executing
Preset Move
command.
Parameter Error •In case of assigned parameter except 0h.
Mode Error
•Not in status of
Camera ON.
•Not in status of
Host Control Mode.