125
13.61 Dome Mode Setting
Camera Control Command Type 2
Function
Sets the dome mode to the designated value.
Command
00BDh
Length
4 byte
Parameter
Range
0000h~0003h
0000h~0001h (Ver.6-08 and up)
Status None
Reference •Dome mode setting value
00h: Select cam path 0 to 9
01h: Select cam path 0 to 8
02h: Select cam path 0 to 7
03h: Select cam path 0 to 6
•Setting value of cam path 0 to 9
0: INF
1: 830cm
2: 380cm
3: 240cm
4: 230cm
5: 155cm 6: 86cm
7: 27.2cm 8 :7.3cm 9 :0.7cm
[Ver.6-08 and up]
0000h: Dome mode OFF
0001h: Dome mode ON
•The Dome mode setting is retained even after the power is turned off.
Format of Control Code
d0 d1
d2 d3 d4 d5
d6
d7 d8 d9
Header
Device Num
Command
Parameter
End mark
FFh 30h
3Xh 00h BDh
30h 30h p0 p1 EFh
⇓
The Dome setting value is expressed as a two-digit hexadecimal number with the
ASCII code as the status value.
Example: p0 p1
Doom mode :
01h
⇒
30h 31h
Doom mode :
03h
⇒
30h 33h
Answer Format
d0 d1 d2 d3 d4 d5
Header
Device Num
Error Code
End mark
FEh 30h 3Xh e0 e1 EFh
⇓
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value
Example: e0 e1
In case of No Error :
00000000B
⇒
00h
⇒
30h 30h
In case of Parameter Error :
01010000B
⇒
50h
⇒
35h 30h
In case of Mode Error :
10010000B
⇒
90h
⇒
39h 30h
Conditions for setting of error flag
Parameter Error •In case of assigned parameter illegal
Mode Error
•Not in status of
Camera ON
•Not in status of
Host Control Mode