116
13.52 Setting Insertion of Infrared Cut Filter
Camera Control Command Type 2
Function
Sets the status when infrared cut filter is inserted.
Command
00B5h
Parameter length
1 byte.
Parameter
Parameter value
1h
Status
None
Reference
•Once this command is received, the filter insertion process and the built-in
infrared light LED OFF process are both performed simultaneously.
Format of Control Code
d0 d1
d2 d3 d4 d5
d6
Header
Device Num
Command
Parameter
End mark
FFh 30h
3Xh
00h B5h 31h
EFh
Answer Format
d0 d1
d2 d3 d4 d5
Header
Device Num
Error Code
End mark
FEh 30h
3Xh e0 e1 EFh
⇓
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
No Error :
00000000B
⇒
00h
⇒
30h 30h
Busy :
00010000B
⇒
10h
⇒
31h 30h
Parameter Error :
01010000B
⇒
50h
⇒
35h 30h
Mode Error :
10010000B
⇒
90h
⇒
39h 30h
Conditions for setting of error flag
Busy
•Filter insertion/removal operation is in progress.
Parameter Error •The designated parameter is an invalid value.
Mode Error
•Not in status of
Camera ON.
•Not in status of
Host Control Mode.
•This command was received while
filter was inserted.