117
13.53 Settings when Infrared Cut Filter Not Inserted
Camera Control Command Type 2
Function
Sets the status when infrared cut filter is not inserted.
Command
00B5h
Length
1 byte.
Parameter
Value
0h
Status
None
Reference
Format of Control Code
d0 d1 d2 d3 d4 d5
d6
Header
Device Num
Command
Parameter
End mark
FFh 30h
3Xh 00h B5h 30h
EFh
Answer Format
d0 d1 d2 d3 d4 d5
Header
Device Num
Error Code
End mark
FEh 30h 3Xh e0 e1 EFh
⇓
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :
00000000B
⇒
00h
⇒
30h 30h
In case of Busy :
00010000B
⇒
10h
⇒
31h 30h
In case of Parameter Error :
01010000B
⇒
50h
⇒
35h 30h
In case of Mode Error :
10010000B
⇒
90h
⇒
39h 30h
Condition of Error flag to be set
Busy
•Filter insertion/removal operation is in progress
Parameter Error •In case of assigned parameter illegal
Mode Error
•Not in status of
Camera ON.
•Not in status of
Host Control Mode.
•This command was received while
filter was inserted.