121
Operation settings for external device output and for external device input triggered events.
External Device Output
Set the operation for output to the external device.
The camera has two external device outputs. It is possible to set the output for each of them.
Note
• The output for an external device can be switched between active and inactive with [External Device Output] of the Camera Viewer
[Operation Mode]
Select whether the output terminals are normally open or closed.
If [Normally Open] is set, an active event occurs when the output terminal connection closes, and an inactive event occurs
when the output terminal connection opens.
If [Normally Close] is set, an active event occurs when the output terminal connection opens, and an inactive event occurs
when the output terminal connection closes.
[Active Output Format]
Select the output format when the external device output is active.
[Pulse Output Time (sec)]
Enter the output duration time (sec.) when [Active Output Format] is set to [Pulse].
External Device Input
[External Device Input Event]
Select whether to use the input from an external device, such as a connected sensor, as an event.
[Event] > [External Device]
Important
• When [Active Output Format] is set to [Pulse] and a timer is used (P. 124), contact output is controlled only once when the timer starts.
HM4x
Normally Open
Active Event Status
Inactive Event Status
1 (The contact is closed.)
0 (The contact is open.)
Normally Close
Inactive Event Status
Active Event Status
1 (The contact is closed.)
0 (The contact is open.)
Содержание VB-H47
Страница 194: ...194 Z Zoom 36 38 ...