3-10
COPYRIGHT © CANON ELECTRONICS INC. 2018 CANON DR-G2140/G2110/G2090 FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
III. UPPER UNIT-1 (MECHANICAL RELATION)
1. Pickup Unit
1) Remove the eject tray unit.
2) Remove the upper front cover.
3) Open the pickup roller cover, and remove
2 screws
1
(M3x6, self-tapping) and the
screw
2
(M3-bind head, round tip) for
pickup sensor position adjustment.
Figure 3-301
4) Remove the cables
1
2
connected to the
pickup motor and pickup sensor.
Figure 3-302
5) Remove 3 cables
1
connected on the
main drive PCB.
Figure 3-303
4) Remove the screw
1
(M3-bind head,
round tip) and remove the ground plate
2
.
Then, remove 4 screws
3
(M3-TP head,
round tip) and remove the pickup unit
4
.
Figure 3-304
Notes on assembling
Finally, install the ground plate at the orig-
inal position, and tighten the screw
2
(M3-bind head, round tip) for pickup sen-
sor position adjustment which was
removed in step 3, to the extent that it does
not become loose. If they are tightened ex-
cessively, the position of the pickup sensor
Содержание imageFORMULA DR-G2140