COPYRIGHT © CANON ELECTRONICS INC. 2018 CANON DR-G2140/G2110/G2090 FIRST EDITION
3-11
CHAPTER 3 DISASSEMBLY & REASSEMBLY
changes or the pickup sensor mounting
plate deforms.
Adjustment after assembly
If the pickup sensor malfunctions after as-
sembly, adjust the position of the pickup
sensor. Refer to “CHAPTER 5 TROUBLE-
SHOOTING, VI. AFTER REPLACING
PARTS” for details.
2. Pickup Roller Cover
1) Remove the pickup unit.
2) Unhook 2 pairs of the fitting parts
1
and
remove the pickup roller cover
2
.
Figure 3-305