System 236E Installation Instructions
22
CL 28 and A0
Command Location 28: Duress Code
0
0
0
0
(1) (2) (3) (4)
Default Values
2 8
Digit Position (1 - 4): Duress Code
This 4-digit code is active only if the system is armed. Entering the Duress Code will disarm the system while sending a
Duress Report to the Central Station. Duress Reports are sent as User #8. Report Routing will be the same as that
specified for Panic Reports (CL 19 Digit Position 3).
NOTE: The Duress Code is Installer programmable only.
Command Location A0: Test Report Countdown Timer
(1)
A 0
Digit Position (1): Set Test Report Countdown Timer
This command sets the time when the first Test Report is transmitted to the central station. The System 236E will use
this transmission time whenever it is powered up or the CPU is reset (unless CL A0 is reprogrammed).
Example:
The time is 1500 hours (3:00 pm). You want the first Test Report to
transmit at 0100 hours (1:00 am). 3:00 pm + 10 hours = 1:00 am.
Program the value "8" in Position (1) of CL A0.
0 = 1/4 hour
1 = 1/2 hour
2 = 1 hour
3 = 2 hours
4 = 3 hours
5 = 4 hours
6 = 6 hours
7 = 8 hours
8 = 10 hours
9 = 24 hours
0 = 14 hours
1 = 16 hours
2 = 18 hours
3 = 20 hours
4 = 22 hours
5 = 24 hours