15
System 236E Installation Instructions
CL 15 and 16
Command Location 15: Event Reports
1
9
D
F
E
(1) (2) (3) (4) (5)
Default Values
1 5
Digit Position (1): Event Report Receiver Select
Shunts, All Restores, Status, Trouble, and Cancel
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
Digit Position (2): Loop Shunt Report Code
Valid entries are 1 - F.
This is a 1-digit reporting code used for all loops.
For 2-digit reporting formats, the loop number will be automatically added as an extension.
Programming a "0" in Position (2) disables shunt reporting for all loops.
Digit Position (3): Cancel Report Code
Valid entries are 1 - F.
This is a 1-digit reporting code used for all loops.
For 2-digit reporting formats, the User ID Number will be automatically added as an extension.
Programming a "0" in Position (3) disables cancel reporting for all loops.
Digit Position (4): Trouble Report Code
Valid entries are 1 - F.
This is a 1-digit reporting code used for all loops.
For 2-digit reporting formats, the loop number will be automatically added as an extension.
Programming a "0" in Position (4) disables trouble reporting for all loops.
Digit Position (5): Loop Restore Reporting Code
Restores are sent for alarm, shunt, and trouble.
Valid entries are 1 - F.
This is a 1-digit reporting code used for all loops.
For 2-digit reporting formats, the loop number will be automatically added as an extension.
Programming a "0" in Position (5) disables restore reporting for all loops.
Command Location 16: Opening/Closing Reports
1
B
C
(1) (2) (3)
Default Values
1 6
Digit Position (1): Opening/Closing Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
Digit Position (2): Opening Report Code
Valid entries are 1 - F. Programming a "0" in Position (2) disables opening reports.
This is a 1-digit reporting code. For 2-digit reporting formats, the User ID Number will be
automatically added as an extension.
Digit Position (3): Closing Report Code
Valid entries are 1 - F. Programming a "0" in Position (2) disables opening reports.
This is a 1-digit reporting code. For 2-digit reporting formats, the User ID Number will be
automatically added as an extension.
(4) (5)
0
0
Digit Position (4 - 5): Duress Report Code
Valid entries are 1 - F.
Program "00" in these digits to disable Duress reporting.
NOTE:
When Duress is enabled, this report will use the same
Report Routing as programmed for "Panic". See CL 19, Digit (3).