System 236E Installation Instructions

24

Keypad  Operation  Command  Summary

The majority of the keypad commands apply equally to the LED and Alpha (LCD) keypads.  Some keypad commands, however, apply to

the LED keypad only, while others are for the Alpha keypad only.
The following Keypad Commands apply to both the LED and Alpha keypads:

Function

Comments

Keystroke Sequence

Arm/Disarm

Delays active

[Combination][#]

Bypass  Zone  (n)

[n]  is  zone  #  1  -  6;  Combo  may  be  required

[Combination][*][2][n][#]

Chime  On/Off

Combination  may  be  required

[Combination][*][5][#]

(Global,  all  keypads)

Change  Combo

Must  be  done  from  Master  Combination

[Master  Combo][*][0][#][User  No.][#]

(User  #1)

[New  Combo][#][New  Combo][#]

Clear  Alarm  Memory

[*][1][#]

Entry/Exit  Pre-Alarm

Toggle  Pre-Alarm  tones  on  and  off

[*][5][2][#] 

(Local  keypad  only)

Error  Tones

Toggle  Error  Tones  on  and  off

[*][5][4][#] 

(Local  keypad  only)

Exit  Programming

[*][#]

Home  Arm

All  interior  zones  are  shunted  simultaneously;

[Combination][*][4][#]

Exterior  zones  armed;  Combo  may  be  required

Instant  Arm

Converts  all  delayed  zones  to  instant;  Combo

[Combination][*][7][#]

may  be  required

Instant  Home  Arm

Arms  exterior  zones,  shunts  interior  zones,

[Combination][*][4][7][#]  (or)

Entry  delays  converted  to  Instant;  Combo

[Combination][*][7][4][#]

may  be  required

Keypad  Activated  RPS

If  enabled,  CL  09(4);  Combo  may  be  required

[Combination][*][0][2][#]

Keypad  Tone  Disable

Toggle  keypress  tones  on  and  off

[*][5][1][#] 

(Local  keypad  only)

Reset  Aux  Power

If  resettable  devices  are  connected  to

[*][6][2][#]

Terminals  labelled  AUX  (+)  and  C

Reset  Panel

Panel  must  be  disarmed

[Master  Combination][*][6][8][#]

Test  -  Battery

Use  after  correcting  Low  Battery  problem

[*][6][4][#]

Test  -  Bells

Combo  may  be  required

[Combination][*][6][3][#]

Test  -  Central  Station

Combo  may  be  required

[Combination][*][6][1][#]

Test  -  Local  Walk  Test

Combo  may  be  required

[Combination][*][6][0][#]

      NOTE:

  For  additional  information  about  Combination  Command  requirements,  see  page  26  and  CL  08  (5).

The  following  Keypad  Commands  apply  to  the  Alpha  keypad  only:

Function

Comments

Keystroke Sequence

Backlight  Toggle  On/Off

[*][8][#]

Display  Keypad  Model

[*][9][#]

    &  Revision  Number

Chime  Toggle

Local  keypad  only

[*][5][3][#]

Panic  Alarm

Keypad  activated

[P]  (Police  soft  zone  key)

The following Keypad Commands apply to the LED Keypad only:

Function

Comments

Keystroke Sequence

Panic  Alarm

Keypad  activated

[7]  &  [9]  (Press  Simultaneously)

Send  Message  to

Message  is  pre-programmed  by  Installer

[*]  &  [#]  (Press  Simultaneously)

  Pager

Toggle  Keypad  Chime

Local  keypad  only

[*][5][3][#]

The following Keypad Commands are Installer Only Commands:

Function

       Comments

Keystroke Sequence

Alpha  Keypad  Programming

Start  Programming  the  Keypad

[Installer  Combination][*][0][1][#]

Alpha  Keypad  Test

Keypad  must  be  disconnected  from  panel

[*][6][7][#]

Kill/Revive Panel

Panel  must  be  disarmed

[Installer  Combination][*][6][9][#]

Panel  Programming

Start  Programming  the  Panel

[Installer  Combination][*][0][#]

Содержание 236E

Страница 1: ...liant RJ 31X or RJ 38X Plug and Jack Red Incoming Ring R Green Incoming Tip T Gray Seized Ring R1 Brown Seized Tip T1 Blue Tamper Orange Tamper POWER SUPPLY INFORMATION Use only 12 VDC 6 5 A H or 4 0 A H sealed lead acid battery Replace battery every 4 6 years with C K Model 1265 or Model 1240 6 5 A H standby battery time with 1 keypad is 24 hours at 150 mA Power demand for AUX POWER keypads and s...

Страница 2: ...Ifitisdeterminedthattheequipmentismalfunctioning discontinueitsuseuntilthe malfunctionhasbeencorrected Anyrepairsoralterationsmadebytheuserofthis equipment orequipmentmalfunctions maygivethetelephonecompanycause torequesttheusertodisconnecttheequipment Repairstothisequipmentshould be made by an authorized agent of C K Systems Inc Contact tour local alarm installationcompanyforservice Should this e...

Страница 3: ...t alarm 3 Fire zones must be programmed for 3 pulse temporal audible alarm 4 Burglar zones must be programmed for a steady audible 5 Burglar loops non 24 hour loops must be programmed for NO NC 6 No Entry Delay may be greater than 45 seconds 7 No Exit Delay may be greater than 60 seconds 8 The Dynamic Battery Test must be enabled 9 The Unit Status Report must be enabled 10 The 24 hour Check in mus...

Страница 4: ... ARMING STATIONS AUDIBLE OUTPUT The BELL Terminal Audible output provides up to 600 mA at 9 5 14 0 VDC For UL installations requiring supervision of the exter nal bell use the C K Model 2350 SUP Bell Supervi sion Kit P N 0 000 231 11 Terminal Label BELL C Available Power The maximum total power available at the BELL AUX and KEY terminals is 800 mA The switched auxiliary and keypads share the same ...

Страница 5: ...te Loops 1 6 0 0 1 5 VDC short 1 6 3 1 VDC normal 3 2 5 0 VDC open System 236E Loop Terminals When programmed as Su pervised EOL an open will be reported as a Trouble whether the system is armed or disarmed A short on a Supervised EOL loop will be reported as an alarm if the system is armed but will have no effect if the system is disarmed SupervisedLoop N C Trouble N O Alarm System 236E Loop Term...

Страница 6: ...ser 2 6 disabled Default installer combination yes Combination required no Faulted Arming type goof proof Opening closing O C reports enabled Reporting Account 1 000000 Dialing type pulse RPS allowed yes Zones Zone 1 entry exit delay EOL circuit Zone 2 interior EOL circuit Zone 3 doors or windows EOL circuit Zone 4 doors or windows EOL circuit Zone 5 doors or windows EOL circuit Zone 6 24 hour sup...

Страница 7: ...n page 8 Remote Programming information can be found in the Commander II Monitor II Operating Manual To Start Keypad Programming Key in the Installer Combination 0 The default installer combination is 0 1 2 3 4 5 On the LED keypad the ARM SERVICE and AC LED s will flash to indicate programming mode PROGRAMMING OPTIONS ThefollowingisanalphabeticallistingofallSystem236Eprogramming options including ...

Страница 8: ...key at these locations the program will advance to CL 29 or CL A1 These locations are not used in the System 236E If you enter CL 29 or CL A1 press to exit programming or press the Command Location followed by the key for the desired programming location To Exit Panel Programming When you have finished programming press The panel will also exit the programming mode if you do not press any key with...

Страница 9: ...ve backward through the messages The Scrolling order of the Alpha Plus messages is SERVICE MESSAGE DEALER MESSAGE SOFT ZONE IDENTIFIER A B and C HARDWIRED LOOP IDENTIFIERS KEYPAD ADDRESS For example to change the Keypad Address Enter Keypad programming as described previously then press BYPASS This will step backwards one step to Keypad Address Enter the New Address followed by the key ALPHA PLUS ...

Страница 10: ...oOpeningandNoClosingReports 1 OpeningandClosingReports 0 NoOpeningandNoClosingReports 1 OpeningandClosingReports Digit Position 3 User 3 O C Report Enable 0 NoOpeningandNoClosingReports 1 OpeningandClosingReports Digit Position 4 User 4 O C Report Enable 0 NoOpeningandNoClosingReports 1 OpeningandClosingReports Digit Position 5 User 5 O C Report Enable 0 NoOpeningandNoClosingReports 1 OpeningandCl...

Страница 11: ...onforBypass InstantArm keypad activatedRPS andTest centralstationandbell Command Location 09 Telco Control Options 0 9 1 1 1 1 0 1 1 2 3 4 5 6 Default Values Digit Position 1 Local System Only 0 No 1 Yes disablesallcommunicationsexceptRPS Digit Position 2 Dialing Attempts 0 4 attempts 1 8 attempts 2 14 attempts Digit Position 3 RPS Enable 0 No 1 Yes allowsremoteprogrammingtostartfromoff premiseloc...

Страница 12: ...ReceiverFormatandMessageFormatarelistedbelow Message Format Receiver Format 3 1Extended Allformats except CFSKIIIandDTMF 1400Hz 4 2 2 digit reporting All formats except CFSK III CFSKIII CFSKIIIonly Pager Pageronly Command Location 0B Account Number 0 B 0 0 0 0 0 0 1 2 3 4 5 6 Default Values Digit Positions 1 6 Account Number Validentriesare0 F Theaccountnumberisrightjustified ThelastdigitmustbeinP...

Страница 13: ...digits 0 dialtonedetect useifmorethanonedialtonemustbedetected 2 DTMFdialingonly notusedinpulsedialing 3 DTMFdialingonly notusedinpulsedialing 4 endofnumber EON 5 5seconddelay Digit 1 is dialed first You must place a 4 EON after the last digit to be dialed FillinremainingPositionswith 0 ZeroesafterEONwill not be dialed Command Location 0D Receiver 1 Phone Number digits 7 12 0 D 0 0 0 0 0 0 1 2 3 4...

Страница 14: ...N after the last digit to be dialed FillinremainingPositionswith 0 ZeroesafterEONwill not be dialed Command Location 10 Receiver 2 Phone Number digits 7 12 1 0 0 0 0 0 0 0 1 2 3 4 5 6 Default Values Command Location 11 Receiver 2 Phone Number digits 13 18 1 1 0 0 0 0 0 0 1 2 3 4 5 6 Default Values Command Location 12 RPS Phone Number digits 1 6 1 2 E 0 0 0 0 0 1 2 3 4 5 6 Default Values Command Lo...

Страница 15: ... Digit Position 5 Loop Restore Reporting Code Restoresaresentforalarm shunt andtrouble Validentriesare1 F Thisisa1 digitreportingcodeusedforallloops For2 digitreportingformats theloopnumberwillbeautomaticallyaddedasanextension Programminga 0 inPosition 5 disablesrestorereportingforallloops Command Location 16 Opening Closing Reports 1 B C 1 2 3 Default Values 1 6 Digit Position 1 Opening Closing R...

Страница 16: ...bled not programmed with 0 will send reports Status Reporting Codes will be a 2 digit code The first digit is the contents of CL 17 1 and the second digit is the Report Code programmed for the specific event Command Location 18 Status Events Reporting Codes 2 1 8 0 0 0 0 0 0 1 2 3 4 5 6 Default Values Digit Position 1 Bell Fuse Fail Report Code 0 No 1 F Yes thisreportcodesentatBellFusefailure Digi...

Страница 17: ...ult Values 1 A Digit Positions 1 2 Test Report Code Validentriesare0 F Programa 00 todisableTestReports Digit Position 3 Test Report Receiver Select 0 Receiver1withReceiver2asback up 1 Receiver1only 2 Receiver2only 3 Receiver1andReceiver2 DualReporting Digit Position 4 Test Report Interval PROGRAMMINGCONVERSIONS Hexadecimal Value Key Strokes A B C D E F 0 1 2 3 4 5 0 Manual SeeNOTE 1 1hour 2 4hour...

Страница 18: ...stant Home orInstant Homearmed Digit Position 6 Autohome Enable 0 No 1 Yes interiorzonesautomaticallyshuntedwhenthesystemisarmedandtheexitdoorisnotused Command Location 1C Loop Alarm Reporting Codes 1 C 1 2 3 4 5 6 1 2 3 4 5 6 Default Values PROGRAMMINGCONVERSIONS Hexadecimal Value Key Strokes A B C D E F 0 1 2 3 4 5 Validentriesare1 F Zonenumberisautomaticallyaddedastheseconddigit Programa 0 todi...

Страница 19: ...y 4 24hours alwaysarmed 5 KeyswitchArming maintained Digit Position 5 Loop Audible Type 1 3PulseTemporal 2 Pulsing 3 Steady 4 Chirp 5 Silent with no LED 6 Silent with LED Digit Position 6 Loop Circuit Type 0 EOL alarmonopenorshort 1 Supervised troubleonopen alarmonshort followsbelltime 2 Supervised belllatched troubleonopen alarmonshort belllatched NOTE A Loop programmed as type 1 or 2 will report...

Страница 20: ...ngoptions Digit Position 6 Loop 6 Shunting Enable RefertoDigitPosition 1 forprogrammingoptions Command Location 25 Delay Before Dial Enable 2 5 0 0 0 0 0 0 1 2 3 4 5 6 Default Values Digit Position 1 Loop 1 Delay Before Dial Enable 0 No 1 Yes thisloopwilldelaydialingonalarmfortimeprogrammedinCL1B 4 Digit Position 2 Loop 2 Delay Before Dial Enable RefertoDigitPosition 1 forprogrammingoptions Digit ...

Страница 21: ...rprogrammingoptions Digit Position 5 User Code 5 RefertoDigitPosition 1 forprogrammingoptions Digit Position 6 User Code 6 RefertoDigitPosition 1 forprogrammingoptions Command Location 27 Keypad Activated Pager 2 7 0 E 0 0 0 0 1 2 3 4 5 6 Default Values Digit Position 1 Enable Keypad Pager 0 No 1 Yes Pressingthe and keyssimultaneouslywillsendthemessageprogrammedinto Digit Positions 2 6 to the page...

Страница 22: ...is Installer programmable only Command Location A0 Test Report Countdown Timer 1 A 0 Digit Position 1 Set Test Report Countdown Timer This command sets the time when the first Test Report is transmitted to the central station The System 236E will use this transmission time whenever it is powered up or the CPU is reset unless CL A0 is reprogrammed Example Thetimeis1500hours 3 00pm YouwantthefirstTe...

Страница 23: ...n advanced design security system it does not offer guaranteed protection against burglary fire or other losses Any alarm system whether commercial or residential is subject to compromise or failure to warn for a variety of reasons These include Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning devic...

Страница 24: ...n 0 2 Keypad Tone Disable Toggle keypress tones on and off 5 1 Local keypad only Reset Aux Power If resettable devices are connected to 6 2 Terminals labelled AUX and C Reset Panel Panel must be disarmed Master Combination 6 8 Test Battery Use after correcting Low Battery problem 6 4 Test Bells Combo may be required Combination 6 3 Test Central Station Combo may be required Combination 6 1 Test Lo...

Страница 25: ... numbers when using keypad programming Answer Hexadecimal values are entered through the use of the key and one of the digits 0 5 For additional help with entering hexadecimal numbers refer to page 7 The hexadecimal conversion chart is also found at various locations throughout the programming section of the manual Question What is an Interface error 1 and how do I correct the error Answer This er...

Страница 26: ...ha keypads with the same address Answer When two keypads have been given the same address a conflict occurs on the data bus since two keypads are trying to communicate at the same time The only way to correct the problem is to disconnect both keypads and then readdress one of them making sure that the address is not used by any other keypad To readdress the keypad enter Alpha Keypad Programming In...

Страница 27: ... system is disarmed With this arrangement any loop which is triggered multiple times while armed will only send one alarm report until the system is dis armed This prevents the system from tying up the phone line with continuous alarm and restoral reports Loop Control 1D 22 4 Loop Arming There may be occasion where it is desirable to program all doors Type and interior points as delayed Or you may...

Страница 28: ...System 236E Installation Instructions 28 C K is a registered trademark of C K Components Inc 1999 C K Systems Inc 5 051 504 00 Rev B www cksys com ...

Страница 29: ...OWER TOTAL 400 mA allowed CONTROL LOCATION BREAKER AND LOCATION KEYPADS Address Location 0 1 2 3 4 5 6 7 0 0 0 1 2 3 4 5 Installer Combination 0 5 0 3 1 0 6 0 4 0 2 0 0 1 0 0 8 Panel Control Options 0 1 0 0 0 0 7 0 2 3 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 User Arming Type 0 0 0 1 User 1 Master Name User 3 Name User 5 Name User 2 Name User 4 Name User 6 Name 1 1 1 0 9 0 Telco Control Options 1...

Страница 30: ...ts 5 1 1 9 D F E B C 1 8 0 0 0 0 0 0 Status Events Reporting Codes 2 7 0 0 0 0 Status Event Reporting Codes 1 1 1 A 0 0 5 1 C 1 2 4 5 6 Loop Alarm Reporting Codes 1 E 1 1 1 3 0 Loop 2 Control 1 3 1 Test Report 9 1 0 0 1 1 Panic Report 1 B 2 3 1 0 0 Timing Keypad Control 1 D 1 1 2 3 0 Loop 1 Control 2 1 2 0 1 1 0 3 0 Loop 4 Control 2 2 1 1 4 1 1 Loop 6 Control 1 0 1 F 1 1 0 3 0 Loop 3 Control 2 1 1...

Отзывы: