www.camplux.com
38
Visit Us: Camplux.com
8350 Patriot Blvd STE B, North Charleston, SC 29420
1(844) 538-7475
Note:
If damages found, please contact a technician to repair or contact Camplux
customer service.
7. Check that all wire connections are firmly in place and there are no signs of
chafing or cracks on the insulation. Verify that the spark
ignition cable between the Control Board and the igniter
is securely in place and not shorted to any metal
component.
8. Inspect the pressure safety valve to ensure it has not
been leaking (no water residue). See "Pressure Safety
Valve Maintenance" for further inspection.
9. Inspect/clean/replace water inlet filter as necessary, use a brush to clean the
filter.
Pressure safety valve maintenance
1. The unit is equipped with a water pressure safety valve.The pressure safety
valve needs to operate once each year to ensure this safety device is effective.
2. The pressure relief valve is a safety component and must not be removed for
any reason other than replacement.
NOTE:
The pressure relief valve must be replaced by a certified service
technician if defective.
WARNING
Burn or scald hazard
●
Never actuate the pressure relief valve while the appliance is in operation.
●
Never tamper with the pressure relief valve.
1. Unscrew the filter.
2. Pull out the filter.
3. Clean the filter with brush.
Safety valve
Filter