Troubleshooting
●
If you encounter a problem with the appliance as the below table states, first try
the suggested solutions. If problems persist, please call the camplux service or
the dealer.
●
Don’t repair the appliance by yourself, repairs must be performed by a certified
service technician.
Potential cause
Solution
No hot water at the tap
Gas supply is turned off or interrupted.
Gas tank is empty.
The appliance is switched off.
Water supply is turned off.
Power supply to the appliance is
switched off.
Defect in the appliance.
1. Cold water mixing into hot water side
2. Higher elevation
3. Incoming water temperature is
abnormally low.
Too much lime scale in the appliance.
Cold water mixing into Hot water side.
Volume flow of hot water is too high
and/or the temperature of cold water
reaching the appliance is too low.
Gas flow to the appliance is too low
(gas inlet pressure 11in. WC).
Check and/or turn on gas supply.
Refill/replace the gas tank.
Switch on the appliance according to instructions
("operating procedures" on page 11).
Open the water supply.
Switch on power supply to the appliance.
Refer to error codes list.
1. Check all valves, inside and outside, to ensure
they are closed, check shower head valve to make
sure it is not partially closed.
2. This is normal due to lesser oxygen levels -
Contact camplux service.
3. See “Water Control Valve" for adjustment.
● Consult vehicle documentation to determine if gas
supply is capable of providing the necessary
volume of gas for the appliance.
● Contact a service technician to verifty a suitable
gas installation.
● Turn down hot water at the tap or in the shower in
order to reduce volume flow. Or mix more cold
water in faucet.
● Potentially retrofit a volume flow throttle into the
water system. This must be performed only by a
certified service technician.
Decalcify your water heater. See "Cleaning and
Maintenance" section.
Hot water takes longer
to reach temperature
Hot water temperature
too low
Problem
Check all valves, inside and outside, to ensure they
are closed. Check shower head valve to make sure
it is not partially closed.
Water escaping at
pressure safety valve
Water pressure in water system too
high.
● Adjust the water pump pressure to a maximum of
65PSI.
● If the water system is connected to a central water
supply higher than 65PSI (rural or urban connection),
a water pressure reducer must be used.
● Install a water pressure regulator at the fresh water
supply.