Hard water and decalcification
For prolong usage, when exposed to higher water hardness concentrations, it is
advised to provide a proper water treatment device for the incoming water to the
coach. Hard water may lead to performance reduction of you appliance overtime.
Contact camplux for decalcification instructions.
Recommended decalcification frequency per year
Troubleshooting
Error Code
If the appliance malfunctions, a beep alarm will sound and the error code will
display on the wall controller. Write down code, then try resolving by stopping and
restart the water flow several times, or resetting the appliance as follows:
●
Switch the power switch in front of the water heater to the “OFF” position (Need
to open the water valve and shower).
●
Wait 5 seconds.
●
Switch the appliance on again.
●
Continue to use the appliance normally. If error fault codes continue to display,
review the following table for potential causes.
3. Tampering with the pressure relief valve will void the
warranty.
4. Rotate the pressure safety valve handle (Red) about
5 times counterclockwise to check if has some water
dripping from the pressure safety valve.
Water hardness mg/l CaCO
3
Very hard: >180
Hard: 121-180
Moderately hard: 61-120
Soft: 0-60
Use*
1
1
1
1
low
2
1
1
1
normal
4
3
2
1
high
Dripping water
Counterclockwise
Pressure safety valve handle