Blown fuse.
Power supply to the appliance is
switched off.
Lime or dirt under the O-ring seats.
Water leaking at the
water inlet filter
Water heater stops
working often and water
is found on the drainage
tray
Power status LED is off
although an operating
mode was selected.
Lime or dirt under the pressure relief
valveseat.
Unit is over heating, and pressure
relief valve discharged periodically.
Switch the standard 125V/10A fuse. Contact
camplux service.
Switch on power supply to the appliance.
Contact camplux service.
Clean the O-ings and their corresponding sealing
surfaces with clean water.
● Allow the appliance to cool then slowly operate the
relief valve by rotating its valve handle (knob),
Fig.36) to flush the water system and attempt to
force dirt or foreign matter out of the pressure relief
valve seat.
● Replace pressure relief valve. This must be
performed only by a certified service technician.