www.camplux.com
18
Visit Us: Camplux.com
8350 Patriot Blvd STE B, North Charleston, SC 29420
1(844) 538-7475
●
Make sure that the operating pressure of the gas supply corresponds to the
operating pressure of the appliance 11~14in-WC (2740~3490Pa).
(a) Locate the entry point for the plumbing to service the rear of the appliance.
Ensure the entry point is not in the footprint space of the appliance.
(b) Feed gas line into proximity, leave enough length to flex into position so that
when connected no kinks are created.
NOTE: An approved semi-flexible metallic pipe is acceptable to connect as an
extension from the gas line to the appliance.
(c) Terminate gas line with fittings to connect to the appliance.
3. Water plumbing
The water plumbing system must be rated to supply between 35-70PSI nominal.
Connections can be made using PEX swivel nut adapters with NPT straight
thread and a cone seal or with a standard ½" FNPT fittings. If use a standard ½"
FNPT fittings for coonection, we suggest you to buy a joint with bottom face seal
(refer to below right side picture), if not, you should buy some Teflon taps for
sealing.
4. Fittings for water inlet and outlet
PEX 1/2" NPT swivel nut
Cone seal rubber
1/2" FNPT fitting
Seal gasket