(b) The required depth “c” depends on how the water hoses, electrical connection
cable, and gas line are installed. The depth “c” must be determined for the
particular situation before installation.
(c) The corners of the rough opening must be at right angles. The exterior wall
opening must be the same dimensions with no rounded corners.
(d) If necessary, create a platform to support the water heater. Below pictures are
some common solutions. Ensure the platform is level front to back, and side to
side after securing to the RV.
Installation plan 2
Down edge of the opening is higher than flooring with one wooden mat.
Note: This cutout size it can replace the Atwood 6-gallon and Suburban 6-gallon tank water heaters.
Cutout dimension on the out wall of the RV
A
12.75″
B
12.75″
C
Min.20″
7"-8"
Wooden mat
Flush platform
(same high)
No radius
RV flooring