www.camplux.com
32
Visit Us: Camplux.com
8350 Patriot Blvd STE B, North Charleston, SC 29420
1(844) 538-7475
Water flow control
1. The appliance is equipped with a water flow control valve in the right side, it set
from the factory at max flow. The valve will reduce the water flow and capacity
through the water heater to improve water heating performance.
Under extreme conditions, it may be necessary to adjust the valve accordingly:
Cold water inlet conditions approximately less than 41°F (5°C)
Higher water inlet pressures > 65 PSI.
Reduce water flow: Rotate knob clockwise until a solid stop.
Increase water flow: Rotate knob counter clockwise until a solid stop.
Fahrenheit unit
Celsius unit
Temperature increase button
Temperature reduction button
Gallons per minute
Power switch button
Power light
Temperature unit
switch button
Operation Instruction
Controller operation
Before normal operation of the appliance, perform a basic functional test check
out each time the RV and water system is setup for use (May sure electric, water
and gas supply are normal).
1. Touch to turn on the power, the display will show current temperature setting.
2. Touch button will transform the temperature display in °F or °C, please see
below picture.
3. Touch button to adjust the temperature to your desired settings. The wall
controller settings are from 95°F (35°C) to 124°F (51°C) ). The default setting
temperature from factory is 108°F (42°C).