www.camplux.com
1
31
Visit Us: Camplux.com
8350 Patriot Blvd STE B, North Charleston, SC 29420
1(844) 538-7475
Functional check
WARNING
Fire or explosion hazard
●
Ensure all necessary system leak tests are complete before operation any
functional test.
●
Failure to follow instruction could lead to serious injury, property damage or death.
Prepare
1. Verify the power switch is in the "OFF" position.
2. Confirm that there is a “steady” water flow (not pulsating) and no air in the
system. If pulsating have the water pump settings adjusted.
3. Make certain all valves that can mix cold and hot water are all shut.
Note:
Outside faucets with detachable spigots and shower heads with flow
interrupters can bleed hot water into the cold side if the valves are not closed
properly. This will hinder the performance of the water heater.
Start to work
1. Turn the power switch to the "
ON
" position on the appliance and verify the wall
controller is illuminated. If the wall controller is not illuminated,press button
on the wall controller to illuminate. The controller d isplay will show the hot
water temperature.
Note:
The default factory setting is 115°F or 46°C.
2. Turn on the gas supply.
3. Open a hot water faucet and verify that the unit ignites and supplies hot water
at the faucet.
4. The wall controller display will show the current temperature settings.
Note:
If any error codes or performance concerns, refer to the troubleshooting
section of this manual.
Fuse
(6A)
Power
switch
Power
switch
button