![Camplux RS264 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/camplux/rs264/rs264_instructions-for-installation-and-use-manual_490365018.webp)
www.camplux.com
1
17
Visit Us: Camplux.com
8350 Patriot Blvd STE B, North Charleston, SC 29420
1(844) 538-7475
●
Fuel entering the appliance must be in the gas phase, the liquid phase must
not be used, and will result in damage to the product.
●
This appliance is rated for 65,000 BTU/HR, 11~14in-WC. (2740~3490Pa).
Follow NFPA1192 and Z240 RV series for proper pipe sizing based on
additional gas-burning appliance loads.
●
Use with LP gas (propane) only. Butane or any mixtures containing more than
10% butane must not be used.
● The gas line must terminate with a ⅜" flared female compression fitting to
connect with the rear gas connector of the appliance.
●
A non Metallic Flexible gas hose must be rated for 149°F (65°C). Anchor
appropriately to prevent fatigue and failure from wear edges.
Prepare utilities
1. Gas supply and connection
DANGER
Fire or Explosion Hazard
●
Follow all applicable codes, regulations, and instruction material when
performing service work.
Failure to follow instructions will result in product damage, serious injury, or death.
20lb gas cylinder
5/8"-18UNF Connector
2. Gas plumbing