Chapter 5: Generic Installation Procedures
Management Connection for MIMO and
Protection Configurations
phn-3962 004v000
Page 5-13
Management Connection for MIMO and Protection
Configurations
In MIMO and all HSB protection configurations, a special signaling cable must be used to connect
the management ports (MGT/PROT) of the two PTP 820C units.
When Out-of-Band management is used, a splitter must be used to connect the management ports
to local management and to each other.
The MIMO/Protection signaling cables are available pre-assembled from Cambium Networks in
various lengths (see
), but you can also prepare them
in the field.
The following sections explain how to prepare and connect these cables.
Preparing a MIMO/Protection Signaling Cable
To prepare your own MIMO/Protection signaling cables, follow the instructions in
Ethernet Cable and Plug-in Field
You must use the following pinouts:
Figure 14 MIMO/Protection signaling cable 1
CAT5E cable
2
4
6
8
RJ-45 connector
(male)
Port1: TX+
Port1: TX-
Port1: RX+
Port1: RX-
Port2: TX+
Port2: TX-
Port2: RX+
Port2: RX-
1
3
5
7
2
4
6
8
RJ-45 connector
(male)
Port1: TX+
Port1: TX-
Port1: RX+
Port1: RX-
Port2: TX+
Port2: TX-
Port2: RX+
Port2: RX-
1
3
5
7
MIMO / Protection
cable pinout:
4
ó
7
5
ó
8
Bl
W/O
G
W/G
Br
W/Br
O
W/Bl
Bl
O/W
G
G/W
Br
Br/W
O
Bl/W
Color Abbreviations
W
– White
G
– Green
O
– Orange
Bl
– Blue
Br - Brown
Connecting a MIMO/Protection Signaling Cable
This option must be used when you plan to manage the system using in-band management.
The MIMO/Protection signaling cable must be connected between the management ports of two
PTP 820C units operating in either MIMO or HSB protection mode. The physical cable connection
Содержание PTP 820C
Страница 1: ...INSTALLATION GUIDE PTP 820C and PTP 820C Assured System Release 10 0 ...
Страница 8: ...Contents phn 3962 004v000 Page vi Scope 8 9 Commissioning Test 8 9 PTP 820 Commissioning Log 8 11 ...
Страница 29: ...Chapter 2 Product Hardware Description MultiCore Mediation Devices MCMD phn 3962 004v000 Page 2 5 Figure 5 OMT ...
Страница 31: ...Chapter 2 Product Hardware Description PoE Injector phn 3962 004v000 Page 2 7 Figure 7 PoE Injector Ports ...
Страница 33: ...Chapter 2 Product Hardware Description System Components phn 3962 004v000 Page 2 9 ...
Страница 193: ...Chapter 6 Installation Procedures per Configuration Type AFR 1 0 Hub Site phn 3962 004v000 Page 6 92 ...