Chapter 6: Installation Procedures per Configuration Type
MultiCore 2+2 HSB Double Polarization Remote
Mount
phn-3962 004v000
Page 6-24
•
Phillips #1 , #2 screwdriver
Insertion Loss
Table 35 Insertion loss for MultiCore 2+2 HSB Double Polarization Remote Mount
Mediation
Devices
Signal
Path/Remarks
Insertion Loss [dB]
6-8 GHz 11 GHz
13-15
GHz
18 GHz
23-26
GHz
28-38
GHz
Double
Coupler,
OMT and
two WGs
Main Paths
2.1
2.1
2.8
3.1
3.4
4
Secondary Paths
6.7
6.7
7.4
7.5
7.8
8
Common Installation
110B
1 Prior
to the installation, follow the antenna manufacturer’s instructions to use the circular
adaptor. (Remove the existing rectangular transition, swap the O-ring, and install the circular
transition instead.)