Chapter 6: Installation Procedures per Configuration Type
MultiCore 2+2 HSB Double Polarization Remote
Mount
phn-3962 004v000
Page 6-23
MultiCore 2+2 HSB Double Polarization Remote
Mount
Note
This procedure can also be used for 2 x MultiCore 1+1 HSB DP HW ready for MultiCore
2+2 HSB DP configurations.
Figure 20 MultiCore 2+2 HSB Double Polarization Remote Mount
List of Items
Table 34 Required items for MultiCore 2+2 HSB Double Polarization Remote Mount
Item Description
Quantity
Remarks
1
PTP 820C RADIO
2
2
PTP 820C OMT KIT
1
3
PTP 820C DUAL COUPLER KIT
1
4
FLEXIBLE WG KIT
2
5
PTP 820C DC POLE MOUNT KIT
1
6
PTP 820C DC REMOTE MOUNT
ADAPTOR KIT
1
From 6-13GHz
7
CIRC./CIRC. ADAPTOR
1
Per Antenna Vendor.
Required Tools
•
Metric offset hexagon key set
•
Metric wrench key set
Содержание PTP 820C
Страница 1: ...INSTALLATION GUIDE PTP 820C and PTP 820C Assured System Release 10 0 ...
Страница 8: ...Contents phn 3962 004v000 Page vi Scope 8 9 Commissioning Test 8 9 PTP 820 Commissioning Log 8 11 ...
Страница 29: ...Chapter 2 Product Hardware Description MultiCore Mediation Devices MCMD phn 3962 004v000 Page 2 5 Figure 5 OMT ...
Страница 31: ...Chapter 2 Product Hardware Description PoE Injector phn 3962 004v000 Page 2 7 Figure 7 PoE Injector Ports ...
Страница 33: ...Chapter 2 Product Hardware Description System Components phn 3962 004v000 Page 2 9 ...
Страница 193: ...Chapter 6 Installation Procedures per Configuration Type AFR 1 0 Hub Site phn 3962 004v000 Page 6 92 ...