Chapter 3: Cable Installation and Grounding
Management Connection for 4x4 MIMO and
1+1/2+2 HSB Configurations
phn-3962 004v000
Page 3-38
Connecting the MIMO/Protection Splitters and Protection
Signaling Cable
Each splitter has three ports:
•
System plug (“Sys”) –
The system plug should be connected to the PTP 8
20C’s management
port.
•
Man
agement port (“Mng”) –
A standard CAT5E cable should be connected to the splitter’s
management port in order to utilize out-of-band (external) management.
Note
Even for systems that use in-band management, initial configuration of a 4x4 MIMO
and any HSB protection configuration must be performed manually using out-of-band
management.
•
MIMO/Protection signaling port (“MIMO/Prot”) –
A MIMO/Protection signaling cross cable, as
described above, should be connected between this port and the other “MIMO/Prot”
port of
the second splitter on the mate PTP 820C unit.
•
The following figure demonstrates a 4x4 MIMO configuration in which both PTP 820C units are
connected to an external management station and to each other, using two splitters.
Содержание PTP 820C
Страница 1: ...INSTALLATION GUIDE PTP 820C and PTP 820C Assured System Release 10 0 ...
Страница 8: ...Contents phn 3962 004v000 Page vi Scope 8 9 Commissioning Test 8 9 PTP 820 Commissioning Log 8 11 ...
Страница 29: ...Chapter 2 Product Hardware Description MultiCore Mediation Devices MCMD phn 3962 004v000 Page 2 5 Figure 5 OMT ...
Страница 31: ...Chapter 2 Product Hardware Description PoE Injector phn 3962 004v000 Page 2 7 Figure 7 PoE Injector Ports ...
Страница 33: ...Chapter 2 Product Hardware Description System Components phn 3962 004v000 Page 2 9 ...
Страница 193: ...Chapter 6 Installation Procedures per Configuration Type AFR 1 0 Hub Site phn 3962 004v000 Page 6 92 ...