Chapter 5: Generic Installation Procedures
Management Connection for MIMO and
Protection Configurations
phn-3962 004v000
Page 5-14
is the same as connecting a CAT5E cable to a system data or management port. For details, see
Connecting a MIMO/Protection Splitter
This option must be used when you plan to manage the system using out-of-band (external)
management rather than in-band management.
The splitter has three ports, as shown in the following figure.
Figure 15 MIMO/Protection signaling cable 2
•
System plug (“Sys”) –
The system plug must be connected to the PTP 820C
’s management
port.
•
Management port (“Mng”) –
A standard CAT5E cable must be connected to the splitter’s
management port in order to utilize out-of-band (external) management.
•
MIMO/Protection signaling port (“MIMO/Prot”) –
A standard CAT5E cable or a
MIMO/Protection signaling cable must be connected between this port and the other
“MIMO/Prot” port of the second splitter on the mate
PTP 820C unit.
The following figures demonstrate a 4x4 MIMO configuration in which both PTP 820C units are
connected to an external management station and to each other, using two splitters.
Содержание PTP 820C
Страница 1: ...INSTALLATION GUIDE PTP 820C and PTP 820C Assured System Release 10 0 ...
Страница 8: ...Contents phn 3962 004v000 Page vi Scope 8 9 Commissioning Test 8 9 PTP 820 Commissioning Log 8 11 ...
Страница 29: ...Chapter 2 Product Hardware Description MultiCore Mediation Devices MCMD phn 3962 004v000 Page 2 5 Figure 5 OMT ...
Страница 31: ...Chapter 2 Product Hardware Description PoE Injector phn 3962 004v000 Page 2 7 Figure 7 PoE Injector Ports ...
Страница 33: ...Chapter 2 Product Hardware Description System Components phn 3962 004v000 Page 2 9 ...
Страница 193: ...Chapter 6 Installation Procedures per Configuration Type AFR 1 0 Hub Site phn 3962 004v000 Page 6 92 ...