Chapter 8: Acceptance & Commissioning Procedures
Radio Link Commissioning Procedure
phn-3962 004v000
Page 8-9
Radio Link Commissioning Procedure
Scope
This section describes the recommended commissioning tests for PTP 820 radio link in a 1+0
configuration.
The purpose of the commissioning tests is to verify correct and proper operation of the product.
Commissioning Test
The following tests should be performed on each installed link.
Link Verification
•
Received Signal Level (RSL) is up to +/- 4 dB from the expected (calculated) level at both ends
of the link.
0F
1
•
Radio Bit Error Rate (BER) is 10E-11 orlower.
•
If working with ATPC, ATPC is operating as expected (RSL = reference level).
Ethernet Line Interfaces Test
•
Connect Ethernet Packet Analyzer to the GbE port. Use physical loop at remote end (or connect
second analyzer). Run Packet Loss test for at least one hour (load rate as per Cambium's
specifications for the chosen MRMC).
•
Connect Ethernet Packet Analyzer to the FE port. Use physical loop at remote end (or connect
second analyzer). Run Packet Loss test for at least one hour (load rate as per Cambium's
specifications for the chosen MRMC).
Interoperability Verification
•
Connect customer end equipment to the line interfaces, and verify correct operation.
•
Further interoperability tests should be performed in accordance with the specific
requirements of the connected end equipment.
1
The voltage at the BNC port is 1.XX where XX is the RSL level. For example: 1.59V means
an RSL of -59 dBm. Note that the voltage measured at the BNC port is not accurate and should be
used only as an aid).
Содержание PTP 820C
Страница 1: ...INSTALLATION GUIDE PTP 820C and PTP 820C Assured System Release 10 0 ...
Страница 8: ...Contents phn 3962 004v000 Page vi Scope 8 9 Commissioning Test 8 9 PTP 820 Commissioning Log 8 11 ...
Страница 29: ...Chapter 2 Product Hardware Description MultiCore Mediation Devices MCMD phn 3962 004v000 Page 2 5 Figure 5 OMT ...
Страница 31: ...Chapter 2 Product Hardware Description PoE Injector phn 3962 004v000 Page 2 7 Figure 7 PoE Injector Ports ...
Страница 33: ...Chapter 2 Product Hardware Description System Components phn 3962 004v000 Page 2 9 ...
Страница 193: ...Chapter 6 Installation Procedures per Configuration Type AFR 1 0 Hub Site phn 3962 004v000 Page 6 92 ...