Chapter 3: Cable Installation and Grounding
Available Cable Options
phn-3962 004v000
Page 3-14
Electrical Requirements
Stranding
Solid
Voltage rating
70V
Shielding
Tinned copper Braid (Coverage: >80%) =
Alluminum Foil
Pinout
Mechanical/ Environmental Requirements
Jacket
UV resistant
Outer diameter
7.1mm (in order to be compatible with the
grounding clamp, CAT5E gnd kit)
Operating and Storage
temperature range
-40°C - 85°C
Flammability rating
According to UL-1581 VW1, IEC 60332-1
RoHS
According to Directive/2002/95/EC
Outdoor DC Cable Specifications
Table 17 Outdoor DC cable specifications
–
Electrical Requirements
Electrical Requirements
Cable type
2
tinned
copper wires
Wire gauge
18 AWG (for <100m installations)
12 AWG (for >100m installations)
Stranding
stranded