Chapter 6: Installation Procedures per Configuration Type
2x2 LoS MIMO Remote Mount
phn-3962 004v000
Page 6-62
2x2 LoS MIMO Remote Mount
Note
This procedure can also be used for 1+0 SD configurations.
Figure 27 2x2 LoS MIMO Remote Mount
List of Items
Table 48 Required items for 2x2 LoS MIMO Remote Mount
Item Description
Quantity
Remarks
1
PTP 820C RADIO
1
2
PTP 820C REMOTE MOUNT
ADAPTOR KIT
1
From 6-13GHz
Required Tools
•
Metric offset hexagon key set
•
Metric wrench key set
Insertion Loss
Table 49 Insertion loss for 2x2 LoS MIMO Remote Mount
Mediation
Devices
Signal
Path/Remarks
Insertion Loss [dB]
6-8 GHz 11 GHz
13-15
GHz
18 GHz
23-26
GHz
28-38
GHz
WGs
PTP 820C antenna
port to antenna
port
Frequency band and WG length (antenna separation)
dependent