Chapter 6: Installation Procedures per Configuration Type
2 x MultiCore 2+0 Dual Polarization Direct
Mount
phn-3962 004v000
Page 6-45
Insertion Loss
Table 41 Insertion loss for 2 x MultiCore 2+0 Dual Polarization Direct Mount
Mediation
Devices
Signal
Path/Remarks
Insertion Loss [dB]
6-8 GHz 11 GHz
13-15
GHz
18 GHz
23-26
GHz
28-38
GHz
Double
Splitter and
OMT
Radio to antenna
port
3.8
3.8
3.8
4
4.2
4.5
Procedure
138B
1
Prior to the installation, follow the antenna manufacturer’s instructions to use the circular
adaptor. (Remove the existing rectangular transition, swap the O-ring, and install the circular
transition instead.)
139B
2 Connect the PTP 820C OMT Kit to the antenna and secure it with four screws. Verify existence
of the O-ring.