59
6.3.9.
Accessories
First touch
SETUP
, then touch
ACCESSORIES
to set up the parameters for the
accessories installed with the system.
A12192
6.3.9.1.
Filter
NOTE
: The daily duct assessment will occur even if static pressure monitoring is
disabled. This is done to ensure that the system will continue to provide proper
airflow for all installed equipment, since duct system changes may occur at any
time, such as opened or closed registers.
With this option, the installer has the option of selecting pressure monitoring, the
type of filter installed, and the time interval for cleaning. After the selections are
made, touch
SAVE
.
S
Pressure Monitoring
(not available or effective with air cleaners that do not
use filter media, such as Electric Air Cleaners): Enable or Disable
d
Default = Enable
S
Clean Interval:
Selectable from 1 to 18 months
d
Default = 3 months
S
Filter Type:
Air Filter, Electric Air Cleaner or Air Purifier
d
Filter type is selected during installation; otherwise default = air filter