Wired Remote Room Sensors
A Remote Room Sensor can be used with the Evolution Connex Control to take the
place of the control’s internal temperature sensor. This allows the Evolution Connex
Control to be mounted in areas with less than optimal airflow (such as near an
exterior door, window or in a closet). The remote sensor can be wired to the
terminal block connectors labeled S1 and S2 at the control’s backplate, or the ZS1
and ZS1C connection at the Damper Control Module. In either case, the Evolution
Connex Control will automatically detect the Remote Room Sensor and ignore its
internal temperature sensor.
NOTE
: Humidity sensing will occur ONLY at the Evolution Connex Control. The
wired Remote Room Sensor does NOT have humidity sensing capability.
4.3.2.1.
Wired Remote Room Sensor Averaging
Typically, one remote sensor is used but, multiple sensors may be used and
averaged in some applications. Averaging requires a special series--parallel wiring
method with a specific number of sensors. See figure below. It is also important to
note the humidity sensor cannot be remotely located, so do not locate the Evolution
Control in an area where humidity sensing may not be accurate.
Содержание Evolution Connex Control
Страница 108: ...99 A160170 NIM Chart...
Страница 109: ...100 A160171 Wiring Diagram Single Stage Non Communicating Heat Pump NIM...
Страница 110: ...101 A160172 Wiring Diagram Two Stage Non Communicating Heat Pump NIM...
Страница 111: ...102 R G FE Fan Coil or Variable Speed Furnace A07114 G Input Wiring for Blower Operation...
Страница 112: ...103 R G FE Fan Coil or Variable Speed Furnace A07115 G Input Wiring for System Shutdown...
Страница 115: ...106 NOTES...