5. Commissioning
This section addresses initial power up (or commissioning) of a new Evolution
Connex Control. The control will communicate and identify all components in the
Evolution System. The following is a typical example for a communicating
variable--speed furnace / fan coil with a 2--stage air--conditioner / heat pump
(including HYBRID HEAT
r
dual fuel system). The process may vary for other
types of systems. See the Evolution System HVAC equipment Installation
Instructions for more details, as provided.
5.1.
Searching for Indoor Unit
The Evolution Connex Control will light up and display the Bryant logo and then
begin the commissioning process by displaying “Searching for indoor unit”.
A12177
NOTE
: If the Evolution System--compatible indoor equipment (package unit
indoor section, gas furnace or fan coil) cannot be found, the control will display
“Indoor unit not found”. This
MUST
be corrected before the initial power up
sequence can continue, proceeding to the next section, “Searching for outdoor
unit.” If it is not corrected, the Evolution Connex Control will go into its
DEMO
operating mode. If a control is operating in Demo mode and you wish to install it
with equipment, navigate to the Installer menu and perform a re--install to re--learn
the equipment.
Содержание Evolution Connex Control
Страница 108: ...99 A160170 NIM Chart...
Страница 109: ...100 A160171 Wiring Diagram Single Stage Non Communicating Heat Pump NIM...
Страница 110: ...101 A160172 Wiring Diagram Two Stage Non Communicating Heat Pump NIM...
Страница 111: ...102 R G FE Fan Coil or Variable Speed Furnace A07114 G Input Wiring for Blower Operation...
Страница 112: ...103 R G FE Fan Coil or Variable Speed Furnace A07115 G Input Wiring for System Shutdown...
Страница 115: ...106 NOTES...