2-104
Confidential
■
Vertical streaks
Fig. 2-13
< User Check >
- Clean the corona wire of all four colors on the drum
unit.
- Return the cleaning tab of the corona wire to the
position.
- This symptom might stop occurring after making
several prints.
- Refer to the User’s guide and remove the dirt on the
exposure drum using a cotton swab.
- Replace the drum unit with a new one.
- Replace the toner cartridge with a new one.
- Wipe the scanner windows of the laser unit with a soft,
lint-free cloth.
Step
Cause
Remedy
1
Dirt in the paper feed system
Wipe dirt off.
2
Installation failure of each FG
wire and/or FG plate
(Grounding is not performed
correctly.)
Retighten the screws of each FG wire and/or
FG plate. Repair the bend of the tray ground
spring of the paper tray.
(See the figure below.)
3
Dirt on the exposure drum
Perform drum cleaning.
(Refer to
“2.2 Drum Cleaning” in Chapter 5
4
Dirt on the cleaner pinch roller
of the fuser cover
Replace the cleaner pinch roller S ASSY.
5
Dirt on the fuser unit
Replace the fuser unit.
6
Laser unit failure
Replace the laser unit.
<Bottom of paper tray>
Paper tray
Tray ground spring
Содержание DCP-L8400CDN
Страница 38: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 Right side Left side Face up Document scanning feed path ...
Страница 249: ...3 85 Confidential 3 Remove the ADF spring from the Upper ADF chute Fig 3 95 ADF spring Upper ADF chute ...
Страница 277: ...3 113 Confidential 9 35 LCD 1 Remove the LCD from the Control panel ASSY Fig 3 145 Control panel ASSY LCD ...
Страница 391: ...5 7 Confidential Common to first and second side Fig 5 1 ...