2-52
Confidential
■
Error code 5001
Number of used pages for the PF kit MP has reached the upper limit. (Printing is not stopped.)
■
Error code 5002
Number of used pages for the PF kit 1 has reached the upper limit. (Printing is not stopped.)
■
Error code 5003
Number of used pages for the PF kit 2 has reached the upper limit. (Printing is not stopped.)
Maintenance
Replace PF Kit MP
Step
Cause
Remedy
1
The PF kit MP is at the end of life
Replace the PF kit MP. After replacing the
PF kit MP, refer to
for parts (Function code 88)” in Chapter 5
and reset the PF kit MP counter.
2
Main PCB failure if the error code
remains after resetting the
counter of the PF kit MP
Replace the main PCB ASSY.
Maintenance
Replace PF Kit1
Step
Cause
Remedy
1
The PF kit 1 is at the end of life
Replace the PF kit 1. After replacing the
PF kit 1, refer to
for parts (Function code 88)” in Chapter 5
and reset the PF kit 1 counter.
2
Main PCB failure if the error code
remains after resetting the
counter of the PF kit 1
Replace the main PCB ASSY.
Maintenance
Replace PF Kit2
Step
Cause
Remedy
1
The PF kit 2 is at the end of life
Replace the PF kit 2. After replacing the
PF kit 2, refer to
for parts (Function code 88)” in Chapter 5
and reset the PF kit 2 counter.
2
Main PCB failure if the error code
remains after resetting the
counter of the PF kit 2
Replace the main PCB ASSY.
Содержание DCP-L8400CDN
Страница 38: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 Right side Left side Face up Document scanning feed path ...
Страница 249: ...3 85 Confidential 3 Remove the ADF spring from the Upper ADF chute Fig 3 95 ADF spring Upper ADF chute ...
Страница 277: ...3 113 Confidential 9 35 LCD 1 Remove the LCD from the Control panel ASSY Fig 3 145 Control panel ASSY LCD ...
Страница 391: ...5 7 Confidential Common to first and second side Fig 5 1 ...