3-173
Confidential
(3) Pull out the MP drive shaft and remove the MP registration front actuator from the MP
upper cover ASSY.
Fig. 3-248
(4) Release the wiring of the MP paper empty/registration front sensor PCB ASSY.
(5) Remove the Taptite bind B M3x8 screw and remove the MP paper empty/registration front
sensor PCB ASSY from the MP upper cover ASSY.
Fig. 3-249
Harness routing: Refer to
MP Paper Empty/Registration Front Sensor PCB ASSY”
MP drive shaft
MP upper cover ASSY
3b
3a
MP registration front actuator
Taptite bind B M3x8
MP upper cover ASSY
MP paper empty/
registration front
sensor PCB ASSY