2-97
Confidential
4.3.2
Troubleshooting image defect
Image defect related problems are end user recoverable if following the User Check items. If
the same problem occurs again, follow each procedure in the order of the number described in
the Step column in the tables below.
■
Light on the whole page
< User Check >
- Check the machine’s environment. High temperature and high humidity
or low temperature and low humidity conditions can cause this problem.
- If the whole page is light, toner save mode may be ON. Turn OFF the
toner save mode.
- Adjust the color calibration from the control panel.
- Replace the drum unit with a new one.
- Replace the toner cartridge with a new one.
- Replace the belt unit with a new one.
- Wipe the scanner windows of the laser unit with a soft, lint-free cloth.
- Leave the machine for a while as the power remains ON.
(Condensation)
- Check if paper is not damp.
Step
Cause
Remedy
1
Dirt on the electrodes of the
main body and the drum unit
Clean the electrodes of the main body and
the drum unit.
(Refer to
.)
2
Dirt on the electrodes of the
high-voltage power supply
PCB
Clean the electrodes of the high-voltage
power supply PCB.
3
Dirt on the density sensor
Clean the density sensor.
4
Density sensor failure
Replace the registration mark sensor unit.
5
Fuser unit failure
Replace the fuser unit.
6
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
7
Main PCB failure
Replace the main PCB ASSY.
Содержание DCP-L8400CDN
Страница 38: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 Right side Left side Face up Document scanning feed path ...
Страница 249: ...3 85 Confidential 3 Remove the ADF spring from the Upper ADF chute Fig 3 95 ADF spring Upper ADF chute ...
Страница 277: ...3 113 Confidential 9 35 LCD 1 Remove the LCD from the Control panel ASSY Fig 3 145 Control panel ASSY LCD ...
Страница 391: ...5 7 Confidential Common to first and second side Fig 5 1 ...